Strona 1 - Reconfigurable I/O

Reconfigurable I/ONI 7831R User ManualReconfigurable I/O Devices for PCI/PXI/CompactPCI Bus ComputersNI 7831R User ManualApril 2004 EditionPart Number

Strona 2

© National Instruments Corporation 1-1 NI 7831R User Manual1IntroductionThis chapter describes the NI 7831R, describes the concept of the Reconfigurab

Strona 3 - Important Information

Chapter 1 IntroductionNI 7831R User Manual 1-2 ni.combetween devices. The NI PXI-7831R accesses the RTSI bus through the PXI trigger lines implemented

Strona 4 - Compliance

Chapter 1 Introduction© National Instruments Corporation 1-3 NI 7831R User ManualOverview of Reconfigurable I/OThis section explains reconfigurable I/

Strona 5 - Contents

Chapter 1 IntroductionNI 7831R User Manual 1-4 ni.comUser-Defined I/O ResourcesYou can create your own custom measurements using the fixed I/O resourc

Strona 6

Chapter 1 Introduction© National Instruments Corporation 1-5 NI 7831R User ManualThe FPGA logic provides timing, triggering, processing, and custom I/

Strona 7 - About This Manual

Chapter 1 IntroductionNI 7831R User Manual 1-6 ni.comYou can use Interactive Front Panel Communication to communicate directly with the VI running on

Strona 8

Chapter 1 Introduction© National Instruments Corporation 1-7 NI 7831R User ManualCables and Optional EquipmentNational Instruments offers a variety of

Strona 9 - Related Documentation

Chapter 1 IntroductionNI 7831R User Manual 1-8 ni.comRefer to Appendix B, Connecting I/O Signals, for more information about using these cables and ac

Strona 10 - Introduction

Chapter 1 Introduction© National Instruments Corporation 1-9 NI 7831R User ManualSafety InformationThe following section contains important safety inf

Strona 11 - Using PXI with CompactPCI

Chapter 1 IntroductionNI 7831R User Manual 1-10 ni.comOperate the NI 7831R at or below the installation category1 listed in the section Maximum workin

Strona 12 - Flexible Functionality

SupportWorldwide Technical Support and Product Informationni.comNational Instruments Corporate Headquarters11500 North Mopac Expressway Austin, Texas

Strona 13 - User-Defined I/O Resources

© National Instruments Corporation 2-1 NI 7831R User Manual2Hardware Overview of the NI 7831RThis chapter presents an overview of the hardware functio

Strona 14 - Software Development

Chapter 2 Hardware Overview of the NI 7831RNI 7831R User Manual 2-2 ni.comFigure 2-2. Parts Locator Diagram for the NI PXI-7831RSW1

Strona 15 - LabVIEW Real-Time Module

Chapter 2 Hardware Overview of the NI 7831R© National Instruments Corporation 2-3 NI 7831R User ManualFigure 2-3. Parts Locator Diagram for the NI PC

Strona 16 - Cables and Optional Equipment

Chapter 2 Hardware Overview of the NI 7831RNI 7831R User Manual 2-4 ni.comInput ModesThe NI 7831R input mode is software configurable. The input chann

Strona 17 - Custom Cabling

Chapter 2 Hardware Overview of the NI 7831R© National Instruments Corporation 2-5 NI 7831R User ManualConnecting Analog Input SignalsThe AI signals fo

Strona 18 - Safety Information

Chapter 2 Hardware Overview of the NI 7831RNI 7831R User Manual 2-6 ni.comFigure 2-4. NI 7831R Instrumentation AmplifierThe instrumentation amplifier

Strona 19

Chapter 2 Hardware Overview of the NI 7831R© National Instruments Corporation 2-7 NI 7831R User ManualTypes of Signal SourcesWhen configuring the inpu

Strona 20 - Hardware Overview

Chapter 2 Hardware Overview of the NI 7831RNI 7831R User Manual 2-8 ni.comFigure 2-5. Summary of Analog Input Connections+–+–V1AI<i>AISENSEAIGN

Strona 21

Chapter 2 Hardware Overview of the NI 7831R© National Instruments Corporation 2-9 NI 7831R User ManualDifferential Connection Considerations (DIFF Inp

Strona 22 - Analog Input

Chapter 2 Hardware Overview of the NI 7831RNI 7831R User Manual 2-10 ni.com Figure 2-6. Differential Input Connections for Ground-Referenced SignalsW

Strona 23 - Input Range

Important InformationWarrantyThe NI 7831R is warranted against defects in materials and workmanship for a period of one year from the date of shipmen

Strona 24

Chapter 2 Hardware Overview of the NI 7831R© National Instruments Corporation 2-11 NI 7831R User Manual Figure 2-7. Differential Input Connections fo

Strona 25

Chapter 2 Hardware Overview of the NI 7831RNI 7831R User Manual 2-12 ni.comYou can fully balance the signal path by connecting another resistor of the

Strona 26 - Types of Signal Sources

Chapter 2 Hardware Overview of the NI 7831R© National Instruments Corporation 2-13 NI 7831R User ManualIn single-ended input modes, electrostatic and

Strona 27

Chapter 2 Hardware Overview of the NI 7831RNI 7831R User Manual 2-14 ni.compositive and negative inputs of the instrumentation amplifier. The instrume

Strona 28 - Signal Sources

Chapter 2 Hardware Overview of the NI 7831R© National Instruments Corporation 2-15 NI 7831R User ManualAnalog OutputThe NI 7831R has eight 16-bit AO c

Strona 29 - Floating Signal Sources

Chapter 2 Hardware Overview of the NI 7831RNI 7831R User Manual 2-16 ni.comFigure 2-10. Analog Output ConnectionsDigital I/OThe NI 7831R has 96 bidir

Strona 30 - (see text)

Chapter 2 Hardware Overview of the NI 7831R© National Instruments Corporation 2-17 NI 7831R User ManualTo interface to 5 V CMOS devices, you must prov

Strona 31

Chapter 2 Hardware Overview of the NI 7831RNI 7831R User Manual 2-18 ni.comFigure 2-11 shows signal connections for three typical DIO applications. Fi

Strona 32 - Sources (NRSE Input Mode)

Chapter 2 Hardware Overview of the NI 7831R© National Instruments Corporation 2-19 NI 7831R User Manualpaired with power or ground. Because the DIO li

Strona 33

Chapter 2 Hardware Overview of the NI 7831RNI 7831R User Manual 2-20 ni.comthe remaining devices on that PXI bus segment must have PXI/TRIG0 configure

Strona 34 - Analog Output

ComplianceCompliance with FCC/Canada Radio Frequency Interference RegulationsDetermining FCC ClassThe Federal Communications Commission (FCC) has rul

Strona 35 - Digital I/O

Chapter 2 Hardware Overview of the NI 7831R© National Instruments Corporation 2-21 NI 7831R User ManualThe left local bus lines from the left peripher

Strona 36

Chapter 2 Hardware Overview of the NI 7831RNI 7831R User Manual 2-22 ni.com4. Reinsert the NI 7831R into the PXI/CompactPCI chassis or PCI computer. R

Strona 37

Chapter 2 Hardware Overview of the NI 7831R© National Instruments Corporation 2-23 NI 7831R User ManualField Wiring ConsiderationsEnvironmental noise

Strona 38 - RTSI Trigger Bus

© National Instruments Corporation 3-1 NI 7831R User Manual3CalibrationCalibration is the process of determining and/or adjusting the accuracy of an i

Strona 39

Chapter 3 CalibrationNI 7831R User Manual 3-2 ni.comIf you have NI-RIO installed, you can find the internal calibration utility at Start»All Programs»

Strona 40 - Switch Settings

© National Instruments Corporation A-1 NI 7831R User ManualASpecificationsThis appendix lists the specifications of the NI 7831R. These specifications

Strona 41 - Power Connections

Appendix A SpecificationsNI 7831R User Manual A-2 ni.comOvervoltage protection ...±42 VData transfers...

Strona 42 - Field Wiring Considerations

Appendix A Specifications© National Instruments Corporation A-3 NI 7831R User ManualSettling TimeCrosstalk...

Strona 43 - Calibration

Appendix A SpecificationsNI 7831R User Manual A-4 ni.comDC Transfer CharacteristicsINL...±0.5 L

Strona 44 - External Calibration

Appendix A Specifications© National Instruments Corporation A-5 NI 7831R User ManualDigital logic levels Maximum output currentImax (source)...

Strona 45 - Specifications

© National Instruments Corporation v NI 7831R User ManualContentsAbout This ManualConventions ...

Strona 46 - Dynamic Characteristics

Appendix A SpecificationsNI 7831R User Manual A-6 ni.comPhase locked to PXI 10 MHzClock(NI PXI-7831R only) ...Adds 350 ps jitter, 300

Strona 47 - Output Characteristics

Appendix A Specifications© National Instruments Corporation A-7 NI 7831R User Manualby the digital outputs use the following equation:Where j is the n

Strona 48 - Voltage Output

Appendix A SpecificationsNI 7831R User Manual A-8 ni.comchassis, tested in accordance with IEC-60068-2-1 and IEC-60068-2-2Relative humidity range...

Strona 49 - Reconfigurable FPGA

Appendix A Specifications© National Instruments Corporation A-9 NI 7831R User ManualSafetyThis product is designed to meet the requirements of the fol

Strona 50 - Power Requirement

© National Instruments Corporation B-1 NI 7831R User ManualBConnecting I/O SignalsThis appendix describes how to make input and output signal connecti

Strona 51 - Operating Environment

Appendix B Connecting I/O SignalsNI 7831R User Manual B-2 ni.comFigure B-2 shows the I/O connector pin assignments for the I/O connectors on the NI 78

Strona 52 - Storage Environment

Appendix B Connecting I/O Signals© National Instruments Corporation B-3 NI 7831R User Manual. Caution Connections that exceed any of the maximum rati

Strona 53 - CE Compliance

Appendix B Connecting I/O SignalsNI 7831R User Manual B-4 ni.com Connecting to CompactRIO Extension I/O ChassisYou can use the CompactRIO R Series Exp

Strona 54 - Connecting I/O Signals

Appendix B Connecting I/O Signals© National Instruments Corporation B-5 NI 7831R User ManualConnecting to 5B and SSR Signal ConditioningNI provides ca

Strona 55

Appendix B Connecting I/O SignalsNI 7831R User Manual B-6 ni.comFigure B-3. Connector Pinouts when Using NSC68-262650 CableThe NSC68-5050 cable conne

Strona 56

ContentsNI 7831R User Manual vi ni.comSingle-Ended Connection Considerations ... 2-12Single-Ended C

Strona 57

Appendix B Connecting I/O Signals© National Instruments Corporation B-7 NI 7831R User ManualNSC68-5050 cable header. In this case, you have access onl

Strona 58

© National Instruments Corporation C-1 NI 7831R User ManualCUsing the SCB-68 Shielded Connector BlockThis appendix describes how to connect input and

Strona 59

© National Instruments Corporation D-1 NI 7831R User ManualDTechnical Support and Professional ServicesVisit the following sections of the National In

Strona 60 - DIO 24–39 Connector

Appendix D Technical Support and Professional ServicesNI 7831R User Manual D-2 ni.comIf you searched ni.com and could not find the answers you need, c

Strona 61 - Shielded Connector Block

© National Instruments Corporation G-1 NI 7831R User ManualGlossarySymbol Prefix Valueppico10–12nnano10–9µ micro 10–6m milli 10–3k kilo 103Mmega106Ggi

Strona 62 - Professional Services

GlossaryNI 7831R User Manual G-2 © National Instruments CorporationSquare root of.+5V +5 VDC source signal.AA Amperes.A/D Analog-to-digital.AC Alterna

Strona 63

Glossary© National Instruments Corporation G-3 NI 7831R User ManualCCCelsius.CalDAC Calibration DAC.CH Channel—Pin or wire lead to which you apply or

Strona 64 - Glossary

GlossaryNI 7831R User Manual G-4 © National Instruments CorporationDIO Digital input/output.DIO<i> Digital input/output channel signal.DMA Direc

Strona 65

Glossary© National Instruments Corporation G-5 NI 7831R User ManualII/O Input/output—The transfer of data to/from a computer system involving communic

Strona 66

GlossaryNI 7831R User Manual G-6 © National Instruments CorporationNnoise An undesirable electrical signal—Noise comes from external sources such as t

Strona 67

© National Instruments Corporation vii NI 7831R User ManualAbout This ManualThis manual describes the electrical and mechanical aspects of the Nationa

Strona 68

Glossary© National Instruments Corporation G-7 NI 7831R User ManualRRAM Random-access memory—The generic term for the read/write memory that is used i

Strona 69

GlossaryNI 7831R User Manual G-8 © National Instruments CorporationTTHD Total harmonic distortion—The ratio of the total rms signal due to harmonic di

Strona 70

About This ManualNI 7831R User Manual viii ni.comprograms, subprograms, subroutines, device names, functions, operations, variables, filenames, and ex

Strona 71

About This Manual© National Instruments Corporation ix NI 7831R User ManualRelated DocumentationThe following documents contain information you might