INSTALLATION GUIDE
NI TB-2708
PXI Terminal Block for S Series Devices
This installation guide describes how to install and connect signals to the
NI TB-2708 terminal block for use with PXI-6115/6120 S Series devices.
Caution The connectors of the TB-2708 are sensitive to electrostatic discharge (ESD). The
user should ground themselves and/or design watchdog timing into their application prior
to connecting or disconnecting signals.
Introduction
The TB-2708 is a terminal block assembly consisting of nine SMB
connectors and a 14-pin I/O connector. The terminal block assembly
connects directly to the front panel of National Instruments PXI-6115
and PXI-6120 devices, eliminating the need for an external cable.
Figure 1. TB-2708 Device View
1 Access Door to Configuration Switches
2 14-Pin I/O Connector (Digital Signals)
3 SMB Connectors (Analog Signals)
AI 0
AI 1
AI 2
AI 3
A
O
0
A
O 1
AI
S
T
AR
T
TRIG
AI
SAMP
CLK
CTR 0
OUT
I
1
2
3
Przeglądanie stron 0
1 2 3 4 5 6 ... 11 12

Podsumowanie treści

Strona 1 - NI TB-2708

INSTALLATION GUIDENI TB-2708PXI Terminal Block for S Series DevicesThis installation guide describes how to install and connect signals to the NI TB-2

Strona 2 - Safety Information

NI TB-2708 Installation Guide 10 ni.comEnvironmentThe NI TB-2708 is intended for indoor use only.Operating temperature ...0 t

Strona 3 - Installation

© National Instruments Corporation 11 NI TB-2708 Installation GuideNational Instruments corporate headquarters is located at 11500 North Mopac Express

Strona 4 - Signal Descriptions

National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal f

Strona 5

NI TB-2708 Installation Guide 2 ni.comThe nine SMB connectors on the TB-2708 allow you to easily connect analog input and analog output signals to you

Strona 6 - Measuring Floating Signals

© National Instruments Corporation 3 NI TB-2708 Installation GuideDo not substitute parts or modify equipment. Because of the danger of introducing ad

Strona 7 - Cabling Options

NI TB-2708 Installation Guide 4 ni.comTo connect the terminal block to the PXI module I/O connector, refer to Figure 2 as you complete the following s

Strona 8

© National Instruments Corporation 5 NI TB-2708 Installation GuideFigure 4. NI TB-2708 Block DiagramFor more detailed descriptions of these signals,

Strona 9 - Specifications

NI TB-2708 Installation Guide 6 ni.comMeasuring Floating SignalsYou can use the TB-2708 to measure floating and ground-referenced analog input signals

Strona 10 - Where to Go for Support

© National Instruments Corporation 7 NI TB-2708 Installation GuideCabling OptionsThis section describes the cabling options for accessing signals on t

Strona 11

NI TB-2708 Installation Guide 8 ni.comTable 4 lists the National Instruments cables available for connecting the TB-2708 to both analog and digital us

Strona 12 - 373785D-01 Apr07

© National Instruments Corporation 9 NI TB-2708 Installation GuideSpecificationsThis section lists the specifications of the TB-2708. These specificat