Appendix D Common Questions
SCXI-1125 User Manual D-4 ni.com
In LabVIEW, can I use a VI to change my filter setting?
In NI-DAQmx, you can change the filter settings using a DAQmx Channel
property node. In Traditional NI-DAQ (Legacy), there is no VI available to
do this. You must use the configuration utility in MAX to configure the
filter setting of each channel.
In C, can I randomly scan the SCXI-1125 using low level Traditional
NI-DAQ (Legacy) function calls?
No, using C, you can scan only consecutive channels using traditional
SCXI channel programming. Refer to the NI-DAQ function reference
manual for more details on SCXI scanning.